Do you have the right size air conditioner
for the room you want to cool?
Check the guide below and see.
Instructions
1. Measure the room to be cooled in
square feet.
2. Select the region (1, 2, or 3) that
best fits your location from the map.
3. Using the chart corresponding to
your region, find the column marked
(Size of Area to be Cooled in square
feet).
4. Reading down the column, select a
number that most closely matches
your room size.
5. Follow this row across to the
column that describes the air
conditioner exposure direction, and
room characteristics.
6. The number you select will be the
approximate btu size needed to
cool your room.
Additional conditions:
· If average occupancy of area is more than two people, add 600 Btu/hour per person. If average is one person, subtract
600 Btu/hour.
· Add 1200 Btu/hour if area includes a kitchen.
· If room is heavily shaded, subtract 10 percent from capacity. Increase capacity by 10 percent if area is very sunny.
Note: For best results, select a room air conditioner with cooling capacity (Btu/hour rating) closest to, but not exceeding,
estimated size.
New
Haven
Albany
Rochester
Fargo
Eugene
Reno
Sacramento
Fresno
Las
Vegas
Flagstaff
Phoenix
Tucson
Pueblo
Wichita
San Antonio
Birmingham
Atlanta
Charlotte
Columbus
Green Bay
1
Region 1
3
Region 3
2
Region 2
R
E
G
I
O
N
1
NORTH OR
SHADED
EAST OR
SOUTH
WEST
Room
Above
Insulated
Ceiling
Non
Insulated
ceiling
Room
Above
Insulated
Ceiling
Non
Insulated
ceiling
Room
Above
Insulated
Ceiling
Non
Insulated
Ceiling
Size of
Area to
be
Cooled
(in
square
feet)
Required Air Conditioner Cooling
Capacity Btu/hour
Required Air Conditioner Cooling
Capacity Btu/hour
Required Air Conditioner Cooling
Capacity Btu/hour
150 3,200 3,500 4,400 5,100 5,400 6,200 6,200 6,500 7,300
200 3,600 4,000 5,200 5,500 5,900 7,000 6,600 7,000 8,100
250 4,000 4,400 5,900 6,000 6,400 7,800 7,100 7,500 8,900
300 4,300 4,900 6,600 6,400 6,900 8,600 7,500 8,000 9,800
350 4,700 5,300 7,400 6,800 7,400 9,400 7,900 8,500 10,600
400 5,100 5,800 8,200 7,200 7,900 10,300 8,300 9,000 11,400
450 5,500 6,200 8,900 7,600 8,400 11,100 8,700 9,500 12,200
500 5,800 6,600 9,600 8,000 8,900 11,900 9,100 10,000 13,000
550 6,200 7,100 10,400 8,400 9,400 12,700 9,500 10,500 13,800
600 6,600 7,600 11,100 8,900 9,900 13,500 10,000 11,000 14,600
650 6,900 8,000 11,800 9,300 10,400 14,300 10,400 11,500 15,400
700 7,300 8,400 12,600 9,700 10,900 15,100 10,800 12,000 16,200
750 7,700 8,900 13,400 10,100 11,400 15,900 11,200 12,500 17,000
800 8,000 9,400 14,100 10,600 11,900 16,700 11,700 13,000 17,800
850 8,300 9,800 14,900 11,000 12,400 17,500 12,100 13,500 18,600
900 8,700 10,200 15,600 11,400 12,900 18,300 12,500 14,000 19,400
950 9,100 10,700 16,300 11,800 13,400 19,100 12,900 14,500 20,200
1000 9,400 11,100 17,100 12,300 14,000 19,900 13,400 15,100 21,000
1100 10,100 12,000 18,500 13,100 14,900 21,400 14,200 16,000 22,600
1200 10,900 12,900 20,000 13,900 15,900 23,000 15,000 17,000 24,200
1300 11,600 13,800 21,500 14,700 16,900 24,700 15,800 18,000 25,800
1400 12,300 14,700 23,000 15,600 17,900 26,300 16,700 19,100 27,400