PCK01A WIRING
T2 T1
L2
L1
FACTORY INSTALLED
BLACK-1
THERMOSTAT
WIRE
LOW PRESSURE
CUTOUT
HIGH PRESSURE
CUTOUT
ASC
PROTECTOR
WIRE NUT
YL-1
CONTACTOR
Y1
Y2
R1
R2
B
L
U
E
Y
E
L
L
O
W
Y
E
L
L
O
W
B
L
A
C
K
-
1
BLUE
Figure 4
1. Remove the factory-installed YL-1 low voltage wire
attached to the coil of the compressor contactor and
thermostat wire connection. Discard.
2. Connect the yellow low pressure cutout wire with the
flag terminal to the field-supplied thermostat wire com-
ing from “Y” indoors. Cut and strip if necessary.
Connect the other yellow low pressure cutout wire to
the stripped end of the blue high pressure cutout wire.
Wire nut the ends and crimp (see Figure 4).
3. Attach the flagged end of the blue high pressure cutout
wire to terminal “R1” on the ASC control.
4. Attach one end of the Black-1 wire provided with the
PCK kit to terminal “R2” on the ASC control. Attach the
other end to the field-supplied thermostat wire coming
from terminal “C” indoors and the factory-installed
Black-1 wire coming from the coil of the compressor
contactor.
5. Attach one end of the YL-1 wire provided with the kit to
terminal “Y1” on the ASC control. Attach the other end
of this wire to the coil of the compressor contactor.
6. Using the wiring diagram (10799001) included in the kit
as a guide, inspect all wiring to ensure that all connec-
tions are tight and no errors have been made.
7. Remove the backing from the wiring diagram. Without
covering the unit wiring diagram, attach the PCK wiring
diagram on the inside of the control box cover.
ASC01A WIRING
T2 T1
L2
L1
BLACK 1
THERMOSTAT
WIRE
SHORT CYCLE
PROTECTOR
Y
ELLOW 1
BLACK 1
Y1
Y2
R1
R2
Y
C
UNIT
TERMINAL
BOARD
CONTACTOR
Figure 5
1. The Black-1 wire provided with the kit includes a
piggyback terminal. Attach this end to “R2” on the short
cycle control.
2. Disconnect the BK-1 wire that runs from unit contactor
to low voltage connection and reconnect this end to the
piggyback terminal on the “R2” terminal of the short
cycle control.
3. Connect the other end of the BK-1 wire supplied with
the kit to the unit contactor (same terminal discon-
nected in step 2 above).
4. Disconnect YL-1 wire at the contactor end and recon-
nect it to the “R1” terminal on the anti short-cycle
control.
5. Connect one end of the YL-1 wire supplied with the kit
to the Y1 terminal on the short cycle control and the
other end to the unit contactor coil terminal vacated in
step 4.
6. Use the anti short-cycle control wiring label, 11036301,
which is included in the ASC kit, as a guide. Inspect all
wiring carefully to ensure that all connections are tight
and no errors have been made.
7. Remove the backing from the anti short-cycle control
label. Without covering the unit wiring diagram, attach
the label on the inside of the control box cover.