a WARNING
To reduce the risk of electric shock, fire, explosion, serious injury or death:
• Disconnect electric power to the dryer before servicing.
• Close gas shut-off valve to gas dryer before servicing.
• Never start the dryer with any guards/panels removed.
• Whenever ground wires are removed during servicing, these ground wires must be
reconnected to ensure that the dryer is properly grounded.
W001
59
RS3200001 (502992R3)
60. THERMAL FUSE (Electric Models)
a. While supporting the lower access panel,
remove two screws from bottom edge of lower
access panel, Figure 51.
b. Gently lower the access panel to disengage
guide lugs from bottom edge of front panel.
c. Disconnect wires from thermal fuse, Figure
26.
NOTE: Refer to appropriate wiring diagram when
rewiring thermal fuse.
d. Set multimeter to read OHMS on the X1
scale. Apply meter probes to the thermal fuse
terminals. Multimeter should read 0 OHMS. If
the meter does not show any reading (infinite
OHMS), then the fuse is open. If the fuse is
open, then replace BOTH the thermal fuse
and the limit thermostat.
61. HEATER ASSEMBLY (Electric Models)
a. While supporting the lower access panel,
remove two screws from bottom edge of lower
access panel, Figure 51.
b. Gently lower the access panel to disengage
guide lugs from bottom edge of front panel.
c. Disconnect wire from heater assembly,
Figure 26.
NOTE: Refer to appropriate wiring diagram when
rewiring heater assembly.
d. Set meter to read OHMS. Apply meter probes
to the heater assembly terminals. Meter
should read as follows: (Cold Ohms)
Color Voltage/Hz. Resistance Reading
Red 240 V 60 Hz. 10.39 ± .31 Ohms cold
White 208 V 60 Hz. 8. 2 ± .5 Ohms Cold