Amana AMH8 Operations Instructions Page 61

  • Download
  • Add to my manuals
  • Print
  • Page
    / 62
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 60
SERVICING
61
2. Check for 24 volts from W to C terminal on the ignition
control. No voltage. Check transformer, room thermo-
stat, and wiring.
If you have 24 volts coming off the transformer but re-
ceive approximately 13 volts on the terminal board be-
tween (C) and (R), check for blown fuse.
3. Check for 120 volts to the induced draft blower by mea-
suring voltage between Pin 1 (on the 2-pin connector)
and neutral located on circuit board. No voltage, check
for loose connection in the 2-pin connector or replace
ignition control.
PCBBF132 Control Board
0130F00006
PARK
PARK
EAC- H L INE- H
XFMR- H
LINE NEUTRAL
L O HEAT- H COOL - H
HI HEAT- H
FAUL T
RECALL
15 0 S EC
1 ST G
AUT O
10 0 S EC
2 STG
5 MIN
H
T
O
F
F
D
L
Y
2
N
D
S
T
G
D
L
Y
MODE
FS
YWR
G
C
K3
K1
K6 K4
K5
K7
K2
WR50M56-289
S-314 CHECKING FLAME SENSOR
A flame sensing device is used in conjunction with the igni-
tion control module to prove combustion. If proof of flame is
not present the control will de-energize the gas valve and
"retry" for ignition or lockout.
Flame Sensor
(80% Upflow Model Shown, Counterflow Similar)