Component Testing Procedures
!
WARNING
To avoid risk of electrical shook, personal injury, or death, disconnect power to oven before servicing, unless
testing requires it.
RT2310001 Rev. 2 February 19972
Illustration Component Test Procedure Results
Oven light socket Test continuity of receptacle terminals.
Measure voltage at oven light.
Indicates continuity with bulb screwed in.
120 VAC, see wiring diagram for terminal
identification.
If no voltage is present at oven light
check wiring.
Oven indicator light Measure voltage at indicator light. If voltage is present and light does not
work replace light.
If no voltage is present at indicator light
check wiring.
Rocker switch Measure voltage at rocker switch to
chassis
120 VAC, see wiring diagram for terminal
identification.
NC
C
Door plunger switch Remove switch from unit and measure
the following point:
C-NC Plunger in infinite, Plunger out continuity.
COM
NC
NO
Hi temperature
latch switch
Test for voltage at terminals to chassis
when in bake, broil, or clean mode.
COM to chassis
Only when latch is engaged:
NO to chassis
120 VAC
120 VAC
AT4
AT3
LINE 1(L)
LINE 2(N)
GROUND
LED clock with minute
and clean timer
Measure voltage at terminals
L1 and N
Remove leads and measure for
continuity.
120 VAC should be indicated.
See schematic
Verify voltage to clock.
If no voltage is present, check wiring.
If voltage is present, replace clock.
Opening
Hinge Carefully open the hinge fully, and
insert a wooden dowel or screwdriver
bit into opening.
Remove top and bottom screws
securing hinge.
Slide hinge top towards rear of unit
and guide hinge out through frame
opening or storage drawer.
CAUTION
!
Do not place hands in hinge area when
oven door is removed. Hinge can snap
closed and pinch hands or fingers.
Norton ignitor Test for voltage at terminals.
Test for the amount of amperage in the
circuit.
(Ignitor may glow but not have
sufficent amperage to open valve).
120 VAC
3.2
3.6 Amps.
Gas valve Disconnect wiring to valve.
Measure resistance on bake circuit.
Measure resistance on broil circuit.
Continuity
Continuity
WARNING
!
Do not attempt to open valve with
120 VAC.