Component Testing Information
!
WARNING
To avoid risk of electrical shook, personal injury, or death, disconnect power to oven before servicing, unless
testing requires it.
February 1997 RT2310001 Rev. 23
Illustration Component Test Procedure Results
Pressure regulator Verify gas pressure (WCP).
If on LP service verify proper gas
supply conversion.
6
Natural
10 LP/propane
H
R
A A
G
Shut off valve Check to verify gas supply is turned
on.
90° valve
Verify gas is supplied.
Orfice adjusted for Natural or LP.
Spark 90° switch
Test for voltage at terminals.
Disconnect wiring and check for
continuity in LITE position.
120 VAC
Continuity in LITE position.
Spark ignition
electrode
Test for resistance of spark lead.
Test ignitor to chassis.
Continuity
No continuity from ignitor to chassis.
Top surface burner Verify gas is supplied.
Verify burner cap is positioned
correctly.
Check for obstructions in burner ports.
Bake burner Verify gas is supplied.
Orfice adjusted for Natural or LP.
Check for obstructions or
contamination in ports.
Broil burner Verify gas is supplied.
Proper orifice installed for Natural or
LP.
Check for damage to screen.
Replace if punctured or torn.
1
2
COM
N.C.
N.O.
BR
BA
9
Gas thermostat
12
7
NO
NC
9BABR
COM
C
Test for voltage at terminals.
LOW
STOP
B
R
500
400
300
200
120 VAC
See wiring diagram.
Venturi Shutter settings
Nominal
Tol. ±
.125 1/8
.031 1/32
Page view 2
1 2 3 4 5 6

Comments to this Manuals

No comments