ATTACH
DUCTWORK
To install ductwork without a wall oven,refer to
Installing Without a Wall Oven instructions.
2
Duct Locations
Cooktop can be vented vertically or horizontally.
If vented horizontally vent air through left or rear
wall.
If vented vertically, inner edge of the vent
must be a minimum of 3/4-inch away from
the wall oven.
Venting must be measured from centerline (CL)
of ductwork to centerline (CL) of cooktop cutout.
Left
exhaust
Rear
exhaust
Vent filler piece
Blower housing front
Duct Connection
Always vent outside. Do not vent into an attic or
crawl space.
Ducting cutout should be 3
1
/2 " x 10
1
/2 ".
Blower exhaust faces towards rear wall from
factory.
Blower can be changed to exhaust to left.
To vent out left side, remove vent filler piece
and move to the rear of the blower.
Refer to Duct Length Calculations for proper
duct length.
Connect blower exhaust to ducting with
standard 3 1/4 x 10-inch duct.
Do not install 2 elbow fittings next to each
other. This creates unusual air patterns and
can result in poor ventilation.
Seal all joints in venting system with duct tape
to avoid smoke or odor in home.
Do not use laundry wall caps. Wall cap must
have minimum of 28 square inches free air
space. Use Amana wall cap model CC30 or
equivalent.
Front
4"
7
1
/
2
"
6
7
/
16
"
Cooktop Side View
7
1
/
2
"
6
7
/
16
"
4"
Cooktop Front View
C
L
C
L