FINAL INSTALLATION CHECK LIST
Dryer is plugged into electrical outlet and is properly grounded.
Exhaust duct work is hooked up and joints taped.
Plastic flexible duct is NOT used.
Use rigid or stiff walled flexible metal vent material.
Dryer is level with all legs firmly on the floor.
Gas Models – gas is turned on, there are no gas leaks.
Start dryer to confirm dryer runs, heats, shuts off.
Demonstrate use to consumer.
6. With a level, check the dryer, and make necessary adjustments to the leveling legs.
7. At this time, make sure all gas connections (on gas models), exhaust and electrical
connections are complete. Plug dryer in, and check operation by using the check list below.
8. (GAS MODELS ONLY)
The burner may not ignite initially due to air in the gas line. Allowing the dryer to operate on a
heat setting will purge the line. If the gas does not ignite within five minutes, turn the dryer off
and wait
5 minutes. Be sure the gas supply to the dryer has been turned on. In order to confirm gas
ignition, check the exhaust for heat.
HOUSEHOLD INSTALLATION ACCESSORIES
Vent hood – 4” (10.16 cm) opening – 059129
Aluminum pipe – 4” x 24” (10.16 cm x 60.96 cm) – 059130
Aluminum elbow – 4” (10.16 cm) – 059131
Aluminum window plate – 15” x 20” (38.10 cm x 50.80 cm) – 4” (10.16 cm) hole – 059134
Flexible aluminum vent duct – 4” (10.16 cm) diameter – 38” (81.28 cm) length stretches to 8’
(2.44 cm) – 304353
Clamp for flexible aluminum duct – 304630
Exhaust duct kit for base or left side exhausting 12002641
Rectangular vent kit – 059144
Dacron lint bag – 311353
NATURAL to LP conversion kit – 306195
LP to NATURAL conversion kit – 306204
Anchor bracket kit – 12002643
Grounding kit – 12001875
Power cords – 240 v, 30 A
4’ (121.9 cm) – 3-wire – 33001780
5’ (152.4 cm) – 3-wire – 33001822
6’ (182.9 cm) – 3-wire – 33001823
10’ (304.8 cm) – 3-wire – 33001838
4’ (121.9 cm) – 4-wire – 33001781
5’ (152.4 cm) – 4-wire – 33001824
6’ (182.9 cm) – 4-wire – 33001825
10’ (304.8 cm) – 4-wire – 33001838