Electrical Connection Requirements
Range must be electrically grounded in accordance with
local codes or in the absence of local codes, with the
National Electrical Code, ANSI/NFPA No. 70-Latest
Edition. In Canada, electrical connections are to made in
accordance with CSA C22.1 Canadian Electrical Code.
Use a 120 volt, 60 hertz, 3-prong receptacle protected by
a 15 amp circuit breaker or time delay fuse. A qualified
electrician should confirm the outlet is properly grounded.
If a 2-prong outlet is encountered, range owner must
replace outlet before using range. Do not cut off cord, use
plug adapter, or remove grounding plug.
Electrical Connection Clearance
Electrical connection must be located in the area shown in
Figure below. Electrical connection must not interfere with
gas connection.
A
BB
CC
D
A—2 inches (Both sides)
B—19½ inches
C—12 inches
D—6 inches
WARNING
To avoid the risk of serious electrical shock or
property damage, do not cut or remove the third
(ground) prong from the power plug. A 3-wire
grounded conductor system must be used. Relying
on the flexible connector, hard piping or any other part
of the gas supply line as a ground may cause fire,
electrical shock and/or erratic control operation.
Rectangular Anti-tip Bracket
1. Measure 3
1
/2 inches from back wall on right and left
side of cabinet cutout. Mark measurements on floor
and draw a straight line connecting marks.
2. Position anti-tip bracket.
If range is installed beside cabinet(s), place anti-tip
bracket with back edge on line drawn on floor and
side of bracket against cabinet.
If range is not installed beside cabinet(s), position
range where it will be installed. Draw a line along
side of range on floor from front to back. Remove
range. Place anti-tip bracket with back edge over
line drawn 3
1
/2 inches from back wall and side of
bracket over line drawn along side of range on floor.
Anti-tip bracket can be installed on either right or
left side.
or
3 1/2"
3. Mark 2 hole locations in anti-tip bracket.
4. Drill 2 holes.
If drilling into wood, use a
3
/32 inch drill bit.
If drilling into concrete, use a
3
/16 inch masonry drill
bit and insert plastic anchors.
5. Secure bracket to floor using screws supplied.
6. Slide range into position.
7. Remove range storage drawer and confirm anti-tip
bracket is engaged with range leveling leg.
Page view 6