Amana ARG7300 Owner's Manual Page 9

  • Download
  • Add to my manuals
  • Print
  • Page
    / 52
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 8
9
Converting for Use with Natural Gas or
Propane Gas
This range arrives from factory adjusted for use with
natural gas. If using LP/propane gas is desired, range
must be converted.
Converting Type 1 Pressure Regulator for Use with
LP/ Propane
1. Remove pressure regulator cap using a
7
/8 inch
wrench.
2. Remove plastic insert from pressure regulator cap.
Plastic insert fits tightly in cap.
3. Reverse plastic insert and carefully push plastic
insert firmly into hole in pressure regulator cap.
Cap must show “LPG10” or “LP10”.
4. Place pressure regulator cap on pressure regulator
and tighten.
Insert should not disturb spring in body of regulator.
Converting Type 2 Pressure Regulator for Use with
LP/Propane
1. Remove pressure regulator cap using a
7
/8 inch
wrench.
2. Reverse pressure regulator cap.
Cap must show “LP”.
3. Place pressure regulator cap on pressure regulator
and tighten.
WARNING
To avoid electric shock that can cause personal injury
or death, disconnect main electrical supply to range
before servicing.