SPECIFICATIONS
HEAT PUMP - PTH
PTH G SERIES
* Actual vent CFM performance will vary due to application and installation conditions.
Notes:
¹ All 265-volt models must use an Amana® brand sub-base (PTSB4**E) or an Amana® brand hard-wire kit (PTPWHWK4).
² Minimum Circui t Ampacity (MCA) ratings conform to the National Electric Code; however, l ocal codes should apply.
Minimum voltage on 230/208- volt models is 197 volts; maximum is 253 volts.
³ Minimum voltage on 265-volt models is 239 volts; maximum is 292 volts.
5
Heating capacity and efficiency based on unit operation without condensate pump; unit automatically switches to electric heat at approximately 24°F outdoor ambient.
6
Specify two-digit heater kW size to complete model number.
7
R-410A refrigerant used in all systems.
8
All units meet or exceed ASHRAE 90.1 standards.
9
All units less than 250 vol ts have a Leak Current Detector Interrupter
(
LCDI
)
power cord and meet UL 484 standards.
10
Refer to electric heat performance data for total MCA and recommended overcurrent protection. Amps and Watts notation refers to compressor onl
y
.
4
Overcurrent protection for all units without electric heaters is 15 amps. Overcurrent protection on 265-volt models must be cartridge-style time-delay fuses
(
included and factor
y
-installed on all Amana® brand 265-volt chassis
)
. See heater performance for total MCA.
EER - Energy Efficiency Ratio per The Air-Conditioning,
Heating, and Refrigeration Institute (AHRI) Test
Procedures and Canadian Standards Association
(CSA) Test Procedures.
COP - Coefficient of Performance per AHRI Test
Procedures
Model ¹,
6
,
8
,
9
PTH
073G**AXXX
PTH
093G**AXXX
PTH
123G**AXXX
PTH
153G**AXXX
PTH
074G**AXXX
PTH
094G**AXXX
PTH
124G**AXXX
PTH
154G**AXXX
230 / 208 230 / 208 230 / 208 230 / 208 265 265 265 265
7,600 / 7,600 9,000 / 9,000 12,000 / 12,000 14,200 / 14,200 7,600 9,100 12,000 14,200
3.9 / 3.9 4.2 / 4.2 5.8 / 5.8 7.0 / 7.0 3.1 3.7 5.0 6.1
650 / 650 785 / 785 1,125 / 1,100 1,465 / 1,445 650 790 1,120 1,465
EER 11.7 / 11.7 11.5 / 11.5 10.7 / 10.7 9.7 / 9.7 11.7 11.5 10.7 9.7
Unit without Electric Heater
4.7 5.1 7.1 8.5 3.8 4.5 6.1 7.4
High 340 330 340 390 340 330 340 390
Low 245 245 245 340 245 245 245 340
High 370 360 370 410 370 360 370 410
Low 270 270 270 370 270 270 270 370
65* 65* 65* 65* 65* 65* 65* 65*
(Compressor & Fan)* 40* 40* 40* 40* 40* 40* 40* 40*
1.7 2.2 3.6 4.4 1.7 2.2 3.6 4.4
108 112 115 126 108 112 115 125
123 127 132 143 123 127 132 142
Voltage ¹, ³
Capacity (BTU/h)
Amps
10
Watts
10
CFM (Dry Coil)
Ventilated Air, CFM (Fan Only)*
Ventilated Air, CFM
Ship Weight (lbs.)
Min. Circuit Amps ²,
4
,
10
CFM (Cool/Wet Coil)
Dehumidification (Pints/Hr.)
Net Weight (lbs.)