PROPER INSTALLATION
the HEAT key until appears, then press
the up and down arrow keys to select ( =
appears in the display).
For the bedroom unit closest to the main room in room
224, press the up and down arrow keys to select
02 (
=
appears in the display) Press the
key to exit configuration mode.
Binding of RF Devices
IMPORTANT NOTE: If wireless platform DP01*, DP01E or
DL01E are being utilized, then room numbers MUST BE CON-
FIGURED in the control board prior to binding wireless de-
vices.
DO NOT ATTEMPT TO BIND
MORE THAN ONE ROOM AT A TIME AT THE
SAME PROPERTY!!!
RF TRANSMITS THROUGH WALLS.
The wireless devices (DS01E and or DD01E must be bound
to the PTAC DT01E control for proper in-room communica-
tion. Ensure the unit is powered but in the OFF position.
NOTE: Both the DS01E and the DD01E must be bound to
the PTAC unit during the same “learn” opera-
tion.
If you need to rebind one device - then you
must rebind both devices during the same
learn mode event.
All must be bound at one time.
1. Press and hold OFF button on the PTAC until appears.
2. Press and then immediately release the white tactile
button on the back of the DS01* thermostat. should
now be displayed on the PTAC LED display. If does
not show on the display in 1-2 seconds, then press and
release the white button a second time. Skip this step
if there is no thermostat.
3. Press and then immediately release the white tactile
button on the back of the DD01* motion sensor.
or
should now be displayed on the PTAC LED display.
If or does not show on the display in 1-2 sec-
onds, then press and release the white button a second
time. NOTE: If both a DD01* and a DS01* are being
bound, then the display will show .
Skip if there is no motion sensor.
4. Press “OFF” on the PTAC touchpad to exit the binding
sequence.
5. Slide top of the thermostat down onto the wall plate
and then snap into place.
6. Provided optional security screws may be used in lower
corners of the thermostat.
OPTIONAL
SECURITY SCREWS
7. Snap motion sensor onto motion sensor mounting plate.
8. Provided optional security screws may be installed on
right and left side of the sensor.
9. If you wish to change from the factory default settings,
configure the device or devices that were bound. See
the next section for configuration choices.
NOTE: If a wireless device is replaced or added, all de-
vices (including those previously bound) will need to be
bound/re-bound to the unit. See directions above.
ENTERING ROOM NUMBER (SKIP IF NOT USING
DP01* FRONT DESK PLATFORM)
1. The PTAC control can be set for a 4-digit room num-
ber. To select the first two digits (floor), press the
HEAT key until appears, then press the
up down arrows to select the first two digits.
2. To select the last two digits of the room number,
press the HEAT key until appears, then