Amana AMV9 Technical Information

Browse online or download Technical Information for Water heaters & boilers Amana AMV9. Amana AMV9 Technical information [en] User Manual

  • Download
  • Add to my manuals
  • Print
  • Page
    / 24
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 0
AMV9/ACV9
40" 90% Gas Furnace Units
C
US
®
Refer to Service Manual RS6300003 Rev. 1 for installa-
tion, operation, and troubleshooting information.
All safety information must be followed as provided in
the Service Manual.
Refer to the appropriate Parts Catalog for part number
information.
Model and manufacturing numbers
listed on page 3.
TECHNICAL INFORMATION MANUAL
®
is a trademark of Maytag Corporation and is used under license to Goodman
Company, L.P. All rights reserved.
Copyright © 2004 Goodman Company, L.P.
RT6612008 Rev. 1
December 2004
This manual is to be used by qualified HVAC technicians only. Goodman
does not assume any responsibility for property damage or personal injury
due to improper service procedures performed by an unqualified person.
Page view 0
1 2 3 4 5 6 ... 23 24

Summary of Contents

Page 1 - TECHNICAL INFORMATION MANUAL

AMV9/ACV940" 90% Gas Furnace Units CUS®• Refer to Service Manual RS6300003 Rev. 1 for installa-tion, operation, and troubleshooting information.•

Page 2 - A M V 9 045 5 B X A

10 Rev. 1PRODUCT DESIGNCoil Matches:A large array of Amana® brand coils are available for use with the new ACV9 furnaces, in either counterflow or hor

Page 3 - PRODUCT IDENTIFICATION

11 Rev. 1PRODUCT DESIGNThermostats:The following Amana® brand thermostats are suggested for use with AMV9 & ACV9 Furnace Models:Thermostat Man/Aut

Page 4

12 Rev. 1PRODUCT DESIGNCounterflow Filters"A"MinReturn AirOptionalAccessDoorThis furnace has provisions for the installation of return air f

Page 5 - COMPONENT IDENTIFICATION

FURNACE SPECIFICATIONS13 Rev. 11. These furnaces are manufactured for natural gas operation. Optional Kits are available for conversion to propane gas

Page 6 - PRODUCT DIMENSIONS

FURNACE SPECIFICATIONS1. These furnaces are manufactured for natural gas operation. Optional Kits are available for conversion to propane gas operatio

Page 7

15 Rev. 1BLOWER PERFORMANCE SPECIFICATIONS1. Units are shipped without filter(s). CFM in chart is without filter(s).2. All furnaces shipped with heati

Page 8

BLOWER PERFORMANCE SPECIFICATIONS16 Rev. 11. Units are shipped without filter(s). CFM in chart is without filter(s).2. All furnaces shipped with heati

Page 9

BLOWER PERFORMANCE SPECIFICATIONS17 Rev. 11. Units are shipped without filter(s). CFM in chart is without filter(s).2. All furnaces shipped with heati

Page 10 - PRODUCT DESIGN

BLOWER PERFORMANCE SPECIFICATIONS18 Rev. 11. Units are shipped without filter(s). CFM in chart is without filter(s).2. All furnaces shipped with heati

Page 11

BLOWER PERFORMANCE SPECIFICATIONS19 Rev. 11. Units are shipped without filter(s). CFM in chart is without filter(s).2. All furnaces shipped with heati

Page 12

PRODUCT IDENTIFICATION2 Rev. 1IF REPAIRS ARE ATTEMPTED BY UNQUALIFIED PERSONS, DANGER-OUS CONDITIONS (SUCH AS EXPOSURE TO ELECTRICAL SHOCK) MAYRESULT.

Page 13 - FURNACE SPECIFICATIONS

BLOWER PERFORMANCE SPECIFICATIONS20 Rev. 11. Units are shipped without filter(s). CFM in chart is without filter(s).2. All furnaces shipped with heati

Page 14

WIRING DIAGRAMS21 Rev. 130 40 50 60 70 80 90 110 120100130 140 150100908070605040302010OUTPUT BTU/HR x 1000BTU OUTPUT vs TEMPERATURE RISE CHARTTEMPERA

Page 15 - AMV9 Heating Speed Charts

BLOWER PERFORMANCE SPECIFICATIONS22 Rev. 1AMV9_____XA (Manufacturing Numbers P1257401-06F), ACV9_____XA (Manufacturing Numbers P1257703-05F)DEHUMWARNI

Page 16 - 16 Rev. 1

23 Rev. 1SCHEMATICSTO AVOID POSSIBLE ELECTRICAL SHOCK, PERSONAL INJURY,OR DEATH, DISCONNECT THE POWER BEFORE SERVICING.WARNING!BLOWER ASSEMBLY SCHEMAT

Page 17 - 17 Rev. 1

24 Rev. 1SCHEMATICSTO AVOID POSSIBLE ELECTRICAL SHOCK, PERSONAL INJURY,OR DEATH, DISCONNECT THE POWER BEFORE SERVICING.WARNING!TYPICAL SCHEMATICAMV9/A

Page 18 - AMV9/ACV9

3 Rev. 1PRODUCT IDENTIFICATIONAMV90453BXA P1257401FAMV90704CXA P1257403FAMV90905DXA P1257405FAMV91155DXA P1257406FMODEL M/N MODEL M/NACV90704CXA

Page 19 - Ramping Profile

4 Rev. 1PRODUCT DESIGN4. Installer must supply the following gas line fittings, de-pending on which entrance is used:Left -- Two 90° Elbows, one close

Page 20

5 Rev. 1COMPONENT IDENTIFICATION1 Two-Stage Gas Valve2 Gas Line Entrance (Alternate)3 Pressure Switch(es)4 Gas Manifold5 Combustion Air Intake Connect

Page 21 - WIRING DIAGRAMS

PRODUCT DIMENSIONS6 Rev. 1AMV9_____XA (Manufacturing Numbers P1257401-06F)AMV9___XAAIRDISCHARGEAIRDISCHARGEALTERNATEGAS SUPPLYHOLELOW VOLTAGEELECTRICA

Page 22 - 24V HUMIDIFIER

7 Rev. 1PRODUCT DIMENSIONSACV9_____XAACV9___BX__ (Manufacturing Numbers P1257703-05F)LOW VOLTAGEELECTRICAL HOLE28 3/43/420 1/42 1/2AIR INTAKE PIPE2&qu

Page 23 - SCHEMATICS

8 Rev. 1PRODUCT DESIGNPart Number 20162903 20162905 20162907 20162908Open Setting (°F)160 145155 170Color Code(s)Blue YellowOrange GreenAMV90453BXA1AM

Page 24

9 Rev. 1PRODUCT DESIGNPart Number10123517 10123518 1012353310123537Open Setting (°F) 210 170 200 190Color Code(s) White Blue Yellow GrayAMV90453BXA1

Comments to this Manuals