RS6612007r1
October 2013
Service Instructions
This manual is to be used by qualified, professionally trained HVAC technicians only. Goodman does not assume any responsibility
for property damage or personal injury due to improper service procedures or services performed by an unqualified
person.The material in this manual does not supercede manufacturer’s installation and operation instructions.
is a registered trademark of Maytag Corporation or its related companies and is used under license.
All rights reserved.
®
®
Copyright © 2006-2013 Goodman Manufacturing Company, L.P.
Goodman
®
& Amana
®
Brand
33 3/8" 80% Modified Two Stage Gas Furnaces
AMH8, GMH8, GDH8, ADSH8
& Accessories
Page view 0
1 2 3 4 5 6 ... 61 62

Summary of Contents

Page 1 - Service Instructions

RS6612007r1 October 2013 Service InstructionsThis manual is to be used by qualified, professionally trained HVAC technicians only. Goodman does not

Page 2 - IMPORTANT INFORMATION

PRODUCT IDENTIFICATION10MODEL # MFG # DESCRIPTIONLPLP03N/ALP Gas Low Pressure Kit. Designed for application on gas fired furnace products installed o

Page 3

ACCESSORIES11MODELNUM BEREFR01AFE180-60AAMU / GMUASAS / GSASSBT14SBT17SBT21LPM-06LPLP02 LPLP03FTK04HA02HANG20HANG21MVK-01MVK-02FSRKG14FSRKG17FSRKG2

Page 4

ACCESSORIES12MODELNUMBEREFR01AFE180-60AAMU / GMUASAS / GSASSBT14SBT17SBT21LPM-06LPLP02 LPLP03FTK04HA02HANG20HANG21MVK-01MVK-02FSRKG14FSRKG17FSRKG21

Page 5

ACCESSORIES13 EXTERNAL FILTER RACK KIT ( EFR01 )BLOWER DECKSCREWSSLOTS IN FILTER CLEAR SCREWSON UNITFRONT OF UNITRETURN AIRCUTOUT AR

Page 6

ACCESSORY WIRING DIAGRAMSHIGH VOLTAGE!DISCONNECT ALL POWER BEFORE SERVICING OR INSTALLING THISUNIT. MULTIPLE POWER SOURCES MAY BE PRESENT. FAILURE T

Page 7

ACCESSORY WIRING DIAGRAMS15HIGH VOLTAGE!DISCONNECT ALL POWER BEFORE SERVICING OR INSTALLING THISUNIT. MULTIPLE POWER SOURCES MAY BE PRESENT. FAILURE

Page 8

16OPERATING INSTRUCTIONSgas. If you then smell gas, STOP!above on this label.Follow "B" in the safety informationabove on this lab

Page 9

17OPERATING INSTRUCTIONSCONSIGNES DE SECURITE - LIREAVANT D'ALLUMER L'APPAREILAVERTISSEMENT: Le non-respect des instructions qui suivent peu

Page 10 - PRODUCT IDENTIFICATION

18OPERATING INSTRUCTIONSDU GAZARRIVEEINLETGASIN "ON" POSLEVER SHOWNMANUAL GAS"ON/MARCHE"MANUEL, EN POSROBINET A GAZ

Page 11 - ACCESSORIES

PRODUCT DESIGN19SafetyPlease adhere to the following warnings and cautions wheninstalling, adjusting, altering, servicing, or operating the fur-nace.T

Page 12

2IMPORTANT INFORMATIONPride and workmanship go into every product to provide our customers with quality products. It is possible, however,that during

Page 13 - ( EFR01 )

PRODUCT DESIGN20CSA International8501 East Pleasant ValleyCleveland, OH 44131A copy of the CAN/CGA B149 Installation Codes can beobtained from:CSA In

Page 14 - ACCESSORY WIRING DIAGRAMS

PRODUCT DESIGN21als, a minimum of 24 inches service clearance must beavailable in front of the unit.A furnace installed in a confined space (i.e., a c

Page 15

PRODUCT DESIGN22COMBUSTION AND VENTILATION AIRREQUIREMENTSWARNINGPOSSIBLE PROPERTY DAMAGE, PERSONAL INJURY OR DEATH MAY OCCURIF THE FURNACE IS NOT

Page 16 - FOR YOUR SAFETY

PRODUCT DESIGN23FurnaceWaterHeaterOpeningChimney or Gas VentOpeningNOTE: Each opening must havea free area of not less than one square inch per 1000 B

Page 17 - OPERATING INSTRUCTIONS

PRODUCT DESIGN24FurnaceWaterHeaterOpeningChimney or Gas VentNOTE: The single opening must havea free area of not less than one square inch per 3000 BT

Page 18

PRODUCT DESIGN25Category I Venting (Vertical Venting)(80% Furnaces Only)WARNINGTO PREVENT POSSIBLE PERSONAL INJURY OR DEATH DUE TOASPHYXIATION, NON-CO

Page 19 - VEHICLE

PRODUCT DESIGN26Checklist SummaryThis checklist serves as a summary of the items to bechecked before venting an 80% furnace into a masonrychimney. In

Page 20 - WHEN INSTALLING THE UNIT

PRODUCT DESIGN27Check 2 - Any solid or liquid fuel appliances ventedinto this chimney channel.Solid fuel appliances include fireplaces, wood stoves, c

Page 21 - EXISTING FURNACE REMOVAL

PRODUCT DESIGN28Check 7 - Complete the Installation.If Checks 1 through 6 have been satisfactory, and the lineris an acceptable size as determined by

Page 22

PRODUCT DESIGN29To install the liner, read and follow the liner manufacturer’sinstructions and your local codes. Excess liner length shouldbe pulled o

Page 23

3IMPORTANT INFORMATION Special Warning for Installation of Furnace or Air Handling Units inEnclosed Areas such as Garages, Utility Rooms or Parking A

Page 24 - PRODUCT DESIGN

PRODUCT DESIGN30High altitude kits are purchased according to the installa-tion altitude and usage of either natural or propane gas.Refer to the produ

Page 25 - CATEGORY III VENTING

PRODUCT DESIGN314. Install a drip leg to trap dirt and moisture before it canenter the gas valve. The drip leg must be a minimumof three inches long.5

Page 26

PRODUCT DESIGN32WARNINGIF THE INFORMATION IN THESE INSTRUCTIONS IS NOT FOLLOWED EXACTLY, AFIRE OR EXPLOSION MAY RESULT CAUSING PROPERTY DAMAGE, PERSON

Page 27

PRODUCT DESIGN333/8" 1/2" 5/8" 3/4" 7/8" 1/2" 3/4" 1" 1-1/4" 1-1/2"10 39 92 199 329 501 275 567 1,07

Page 28

PRODUCT DESIGN34115 VOLT LINE CONNECTION OF ACCESSORIES(HUMIDIFIER AND ELECTRONIC AIR CLEANER)WARNINGHIGH VOLTAGEDISCONNECT ALL POWER BEFORE SERVICING

Page 29

PRODUCT DESIGN35A return air filter is not supplied with the furnace. The in-staller must supply a means of filtering all of the return air.Filter(s)

Page 30

PRODUCT DESIGN36"A"MinReturn AirOptionalAccessDoorCabinetWidthFilter Area(in2)Qty.Filter Size(in)Dimension "A:(in)14 15.117 1/2 14.221

Page 31

PRODUCT DESIGN37• High-stage gas valve closes after five seconds; low-stage gas valve remains open.• Integrated control module monitors flame presence

Page 32

PRODUCT DESIGN38SECONDSTAGEONLYSECONDDELAYSECONDDELAY1-STAGE2-STAGEHEAT OFFDELAYMODEAUTO* Switches for White-Rodgers board shown aboveWith other vende

Page 33

SYSTEM OPERATION39HEATING - Abnormal OperationThe following presents the probable causes of questionablefurnace operation and how to fix them. Look t

Page 34

PRODUCT IDENTIFICATION4The model and manufacturing number are used for positive identification of component parts used in manufacturing.Please use the

Page 35

TROUBLESHOOTING401Integrated control module will automatically attempt to reset from lockout after one hour.2LED Flash code will cease if power to the

Page 36 - HEATING MODE

TROUBLESHOOTING412 LED Flash code will cease if power to the control module is interrupted through the disconnect or door switch.TROUBLESHOOTING CHART

Page 37 - FAN ONLY MODE

POLARIZATION AND PHASING42As more and more electronic's are introduced to the Heat-ing Trade, Polarization of incoming power and phasingof primar

Page 38

43MAINTENANCE WARNINGHIGH VOLTAGEDISCONNECT ALL POWER BEFORE SERVICING ORINSTALLING THIS UNIT. MULTIPLE POWER SOURCES MAYBE PRESENT. FAILURE TO DO SO

Page 39 - SYSTEM OPERATION

MAINTENANCE44FLAME SENSOR (QUALIFIED SERVICER ONLY)Under some conditions, the fuel or air supply can create anearly invisible coating on the flame sen

Page 40 - A/GMH8, GDH8, ADSH8

45MAINTENANCEgas and with proper inlet pressures and correct piping size,full capacity will be obtained.With propane gas, no unit gas valve regulator

Page 41

46SERVICING1/4cu/ft1/2cu/ft1cu/ft2cu/ft5cu/ft1/4cu/ft1/2cu/ft1cu/ft2cu/ft5cu/ft10 90 180 360 720 1800 36 25 50 100 200 50011 82 164 327 655 1636 37 --

Page 42 - POLARIZATION AND PHASING

SERVICING47Service Pr oblem No Hea t Unsatisfactory HeatPOSSIBLE CAUSEDOTS IN ANALYSISGUIDE INDICATE"POSSIBLE CAUSE"SYMPTOMSystem Will Not S

Page 43 - MAINTENANCE

48SERVICINGSERVICE NUMBERSS-1 CHECKING VOLTAGE...

Page 44

SERVICING49S-1 CHECKING VOLTAGEWARNINGHIGH VOLTAGEDISCONNECT ALL POWER BEFORE SERVICING ORCHANGING ANY ELECTRICAL WIRING. MULTIPLE POWERSOURCES MAY BE

Page 45

PRODUCT IDENTIFICATION5MODEL# MFG.# DESCRIPTIONGDH8**CAGDH80453A* GDH80703A* GDH80904B* GDH81155C* Goodman® Brand 80% Modified Two-Stage Gas Furnace,

Page 46 - SERVICING

50SERVICINGIf the anticipator current draw is unknown, then a currentamp draw should be measured to determine the anticipa-tor setting. Use an amprobe

Page 47

SERVICING51S-15A Resistance CheckCAPACITORVOLT / OHM METERTesting Capacitor ResistanceWARNINGHIGH VOLTAGEDISCONNECT ALL POWER BEFORE SERVICING ORIN

Page 48

52SERVICING AmanaElectronic Air Cleaner Ca ution High V oltageTo avoi d per sonal in ju ry, wai t 15 secon ds aft e r de -ene rgizi n

Page 49

SERVICING53S-300 CHECKING PRIMARY LIMIT CONTROLAll use a nonadjustable, automatic reset, bi-metal type limitcontrol. Refer to the following drawing

Page 50

54SERVICINGWARNINGHIGH VOLTAGEDISCONNECT ALL POWER BEFORE SERVICING ORINSTALLING THIS UNIT. MULTIPLE POWER SOURCES MAYBE PRESENT. FAILURE TO DO SO MAY

Page 51 - S-200 CHECKING DUCT STATIC

SERVICING55VOLT / OHM METERGND RED RESETBUTTON COLORIDENTIFYING TABChecking Flame Rollout Switcha. If no voltage is measured on either

Page 52

56SERVICINGOrifices should be treated with care in order to preventdamage. They should be removed and installed with a box-end wrench in order to prev

Page 53

SERVICING57WARNINGHIGH VOLTAGEDISCONNECT ALL ELECTRICAL POWER AND SHUT OFF GASSUPPLY BEFORE SERVICING OR INSTALLING THIS UNIT.MULTIPLE POWER SOURCES M

Page 54

58SERVICING ManometerManometerHoseHigh Fire RegulatorAdjustRegulatorVentMeasuring Manifold Gas Pressure(36G54 Valve)Gas Valve On/OffSelector Switc

Page 55 - MULTIPLE POWER SOURCES MAY

SERVICING59Gas Rate Range NominalHigh Stage 3.2 to 3.8" w.c. 3.5" w.c.Low Stage 1.6 to 2.2" w.c. 1.9" w.c. Manifold Gas PressureN

Page 56

PRODUCT IDENTIFICATION6MODEL # MFG.# DESCRIPTIONGMH8**CAGMH80453A* GMH80703A* GMH80704B* GMH80903B* GMH80904C* GMH80905C* GMH81155C* GMH81405D*Goodma

Page 57

60SERVICINGInduced Draft Blower Pressure SwitchPressure SwitchHose1/4" TeeHose to Induced Draft Blower TapInclined ManometerID Blower Pressure

Page 58

SERVICING612. Check for 24 volts from W to C terminal on the ignitioncontrol. No voltage. Check transformer, room thermo-stat, and wiring.If you have

Page 59

62SERVICING WARNINGHIGH VOLTAGEDISCONNECT ALL POWER BEFORE SERVICING ORINSTALLING THIS UNIT. MULTIPLE POWER SOURCES MAYBE PRESENT. FAILURE TO DO SO M

Page 60

PRODUCT IDENTIFICATION7MODEL# MFG.# DESCRIPTIONAMH8**CAAMH80453A* AMH80703A* AMH80704B* AMH80903B* AMH80904C* AMH80905C* AMH81155C* AMH81405D*Amana®

Page 61

PRODUCT IDENTIFICATION8MODEL# MFG.# DESCRIPTIONADSH80***AAADSH800403AX* ADSH800603AX* ADSH8 008 04 CX* ADSH8 010 05 CX*Amana® Brand 80% Modified Two

Page 62

PRODUCT IDENTIFICATION9MODEL # MFG # DESCRIPTIONAFE18-60AN/ AFossil Fuel Kit. The AFE18-60A control is designed for use where the indoor coil is loca