Component Testing Procedures
!
WARNING
To avoid risk of electrical shock, personal injury or death; disconnect power to oven and discharge capacitor
before servicing, unless testing requires power.
RS2240003 Rev. 0 12
Illustration Component Test Results
Thermal cutout Disconnect all wires from TCO.
Measure resistance across terminals.
Magnetron TCO ...................................
Cavity TCO ..........................................
Open at 300°F (149°C) and closed at
257°F (125°C)
Opens at 262°F (128°C)
Diode
Discharge Capacitor
Remove diode lead from capacitor and
connect ohmmeter.
Reverse leads for second test.
Infinite resistance should be measured
in one direction and 50K or more in
the opposite direction.
NOTE: Ohmmeter must contain a
battery of 6 volts minimum.
MT2
MT1 GATE
Triac
Resistance Check
Disconnect wires to triac.
Measure resistance from:
MT1 to MT2 .........................................
MT1 to Gate.........................................
MT2 to Gate.........................................
All terminals to ground .........................
Caution - Do not operate oven with
wire to terminal MT2 removed.
Infinite
Approximately 60
Infinite
Infinite
Triac 1 (center)
Triac 2 (left)
Triac 3 (right
Voltage Check
Measure voltage from:
MT1toGate
0.8 VAC when energized. If no
voltage, check H.V. board and wiring.
Capacitor
Some unit may use
more then one type of
capacitor, Refer to
Parts Manual for
correct capacitor
quantity.
Discharge Capacitor
Remove wires from capacitor terminals
and connect ohmmeter, set on highest
resistance scale to terminals.
Also check between each terminal and
capacitor case.
Between Terminals: Meter should
momentarily deflect towards zero then
return to over 5 M.Ifnodeflection
occurs, or if continuous deflection
occurs, replace capacitor.
Terminal to Case: Infinite resistance
Snubber assembly Disconnect wires to snubber.
Measure resistance across terminals ........ Infinite
Magnetron
Discharge Capacitor
Remove wires from magnetron and
connect ohmmeter to terminals. Also
check between each terminal and ground.
Between Terminals: Less than 1
Each terminal to ground measures
Infinite resistance.
Note: This test is not conclusive. If
oven does not heat and all other
components test good replace the
magnetron and retest.
Blower motor Remove all wires from motor.
Measure resistance across coil .................
Approximately 25