PRODUCT IDENTIFICATION
2 Rev. 2
The model and manufacturing number are used for positive identification of component parts used in manufacturing.
When engineering and manufacturing changes take place where interchangeability of components are affected, the
manufacturing number will change.
It is very important to use the model and manufacturing numbers at all times when requesting service or parts informa-
tion.
IF REPAIRS ARE ATTEMPTED BY UNQUALIFIED PERSONS, DANGER-
OUS CONDITIONS (SUCH AS EXPOSURE TO ELECTRICAL SHOCK) MAY
RESULT. THIS MAY CAUSE SERIOUS INJURY OR DEATH.
AMANA WILL NOT BE RESPONSIBLE FOR ANY INJURY OR PROPERTY
DAMAGE ARISING FROM IMPROPER SERVICE OR SERVICE PROCE-
DURES. IF YOU PERFORM SERVICE ON YOUR OWN PRODUCT, YOU ASSUME RESPONSIBILITY
FOR ANY PERSONAL INJURY OR PROPERTY DAMAGE WHICH MAY RESULT.
WARNING
WARNING
Product Type
G: Gas Furnace
Supply Type
U: Upflow/Horizontal
Airflow Capability
35: 1.5 - 3.5 Tons
40: 1.5 - 4.0 Tons
50: 2.0 - 5.0 Tons
Nominal Input
070: 70,000 Btuh
090: 90,000 Btuh
115: 115,000 Btuh
Model Family
A: Air Command 90 (40" Height)
Design Series
B: Initial Design Series (Silicon Nitride Ignition System)
G U S A 070 B X 35
Additional Features
X: NOx Models
Furnace Type
S: 2-Stage Condensing (90%)
CAUTION
dimensions of Amana cca18fcc