31
!"#$%!&'!()&*+,-.&/&0+,-.
Pad 8
Mode Name
Service Pad 8
Entry
Pressing Pad 8 while in Service Mode
Functional
Description
Displays Door Cycles stored in EEPROM. Will always be a multiple of
ten.
Display
D o o r
C y c l e s
0 0 2 4 5 3 8 0
Pad 9
Mode Name
Service Pad 9
Entry
Pressing Pad 9 while in Service Mode
Functional
Description
Prompts user to clear service information.
Display
P r e s s S
T A R T t o
C l e a r s e r v . i n f o
Pad 0
Mode Name
Service Pad 0
Entry
Pressing Pad 0 while in Service Mode
Functional
Description
Displays offset used when heating cavity.
Display
T e m p .
O f f s e T
2 0 ° F
TEMP Pad
Mode Name
Display Temperature
Entry
Pressing the Temp Pad in Service Mode.
Functional
Description
Displays temperature as reported by RTD
Display
C a v i t
y T e m P
1 9 4 ° F