Servi
This manual is to be used by qualified appliance
technicians only. Maytag does not assume any
responsibility for property damage or personal
injury for improper service procedures done by
an unqualified person.
Sli e
C
m
|
Air C
e
This Base Manual covers general information
Refer to individual Technical Sheet
for information on specific models
This manual includes, but is
not limited to the following:
Amana
AAC081SRA
AAC101SRA
AAC121SRA
AAC141SRA
AAC182SRA
AAC202SRA
AAC242SRA
16022061
May 2003
Page view 0
1 2 3 4 5 6 ... 41 42

Summary of Contents

Page 1

ServiThis manual is to be used by qualified appliancetechnicians only. Maytag does not assume anyresponsibility for property damage or personalinjury

Page 2 - I _ WARNING I

Troubleshooting informationWARNINGTo avoid risk of electrical shock, personal injury, or death, disconnect electrical power source to unit anddischarg

Page 3 - WARNING ]

Troubleshooting informationWARNINGTo avoid risk of electrical shock, personal injury, or death, disconnect electrical power source to unit anddischarg

Page 4 - Table of Contents

Troubleshooting informationWARNINGTo avoid risk of electrical shock, personal injury, or death, disconnect electrical power source to unit anddischarg

Page 5 - Product identification

Testing ProceduresWARNINGTo avoid risk of electrical shock, personal injury, or death, disconnect electrical power source to unit anddischarge capacit

Page 6

Testing ProceduresWARNINGTo avoid risk of electrical shock, personal injury, or death, disconnect electrical power source to unit anddischarge capacit

Page 7

Testing ProceduresWARNINGTo avoid risk of electrical shock, personal injury, or death, disconnect electrical power source to unit anddischarge capacit

Page 8

Testing ProceduresWARNINGTo avoid risk of electrical shock, personal injury, or death, disconnect electrical power source to unit anddischarge capacit

Page 9

Testing ProceduresWARNINGTo avoid risk of electrical shock, personal injury, or death, disconnect electrical power source to unit anddischarge capacit

Page 10 - Troubleshooting information

Disassembly Procedures[ WARNINGTo avoid risk of electrical shock, personal injury, or death, disconnect electrical power source to unit anddischarge c

Page 11

Disassembly Procedures[ WARNINGTo avoid risk of electrical shock, personal injury, or death, disconnect electrical power source to unit anddischarge c

Page 12

important informationimportant Notices for Servicers and ConsumersMaytag will not be responsible for personal injury or property damage from improper

Page 13 - Testing Procedures

Disassembly Procedures[ WARNING ]To avoid risk of electrical shock, personal injury, or death, disconnect electrical power source to unit anddischarge

Page 14

Disassembly Procedures[ A WARNINGTo avoid risk of electrical shock, personal injury, or death, disconnect electrical power source to unit anddischarge

Page 15

Disassembly Procedures[ ,Ek WARNINGTo avoid risk of electrical shock, personal injury, or death, disconnect electrical power source to unit anddischar

Page 16

Disassembly Procedures[ WARNINGTo avoid risk of electrical shock, personal injury, or death, disconnect electrical power source to unit anddischarge c

Page 17

[]@2003 MaytagAppliancesCompany 16022061 Rev. 0 A-1

Page 18 - Disassembly Procedures

BUILT BETTER THAN IT HAS TO BE'"Owner'sMa.ualRoom Air ConditionerKeep manual for future reference. Be sure manual stays with air condit

Page 19

-- _k WARNINGHiGH TEMPERATURE STRESS HAZARDThis room air conditioner is not meant toprovide unattended cooling or life supportfor persons or animals t

Page 20

Installation Requirements nstaHConsiderLocationElectrical RequirementsSpecial ConsiderationsDescriptionFor proper air conditioner operation all vents

Page 21

Do you have the right size air conditionerfor the room you want to cool?Check the guide below and see.InstructioRs1. Measure the room to be cooled ins

Page 22 - [ CAU'nON J

Size ofArea tobeCooled(inR squarefeet)15020025030035O4OO| 450500O 5506OO65O70075O80065O2 90095010001100120013001400NORTH OR EAST ORWESTSHADED SOUTH9.-

Page 23

important Safety informationGeneral InformationThis Service Manual describes the operation,disassembly, troubleshooting, and repair of AmanaRoom Air C

Page 24

You'll Need a Few Things Before You Begin _^ Drill andToolsKnifePhillips ScrewdriverStandard Putty Knife IGlovesLevelTape Measure _1/16" Dri

Page 25 - Owner's

Important SafetyInformationAbout Ground WiresIn the event of an electrical short circuit, aground wire reduces the risk of electricshock by ploviding

Page 26 - -- _k WARNING

PREPAREWINDOW FORiNSTALLATiONInspect window track, sash, and sillfor its ability to support the weight ofair conditioner.Measure width between windowm

Page 27 - Description

INSTALL SEALGASKETCut window seal gasket to width ofwindow. Stuff window seal gasketbetween outdoor window glassand top of indoor sash. This willstop

Page 28

ASSEMBLECU RTAi N S/TO PRAiLRemove paper backing from top railgasket and adhere to bottom of top rail.Install top rail with three or four 10-mmscrews

Page 29 - 16022061 Rev. 0

iNSTALL OUTERCASE IN WINDOWPlace outer case in window. Lower sashuntil it rests behind front flange of top rail.Bottom rail must rest behind window si

Page 30 - .ountin=--.w

RETURNCHASSIS TOOUTER CASEFind someone to help you replacechassis in outer case. Installbasepan clip. Replace front paneland grille. Where possible, i

Page 31 - G oundmg Instructions

Thru-wai| installation instructionsCAUTIONinstalling air conditioner through a wall requiresextensive carpentry and/or masonry experience.Through wall

Page 32 - _ 'i 0DTu

V. Normal Care and Maintenance_, WARNINGTo reducethe riskofelectricshock, personalinjury, or death, turn the fan control to theoff position and remove

Page 33 - I -" /

VI. General Operating instructionsThe operation and control of all units are very similar;however, they do vary slightly from model to model. SectionV

Page 34 - 44" (AAC18, AAC20)

Table of ContentsImportant Information ... 2Important Safety Information ...

Page 35 - GASKET _ /

Before Calling For Service_Pm WARNINGo reduce the risk of electric shock, personal injury, or death, turn the fan control to the offosition and remove

Page 36 - OUTER CASE

When Service is RequiredFor answers to questions or to locate an authorized servicer,call 1-800-NAT-LSVC (1-800-628-5782t inside USA or319-622-5511 ou

Page 37

WarrantyROOM AIR CONDITIONERFULL ONE YEAR WARRANTYBU,. e=TT_RTHA.,THASTOB_' FULL FIVE YEAR WARRANTY ON SEALED SYSTEM COMPONENTSFIRST YEARAmana wi

Page 38 - _, WARNING

Product identificationEvery Amana ® Room Air Conditioner has anidentification plate showing the model number, P(manufacturing part) number, serial num

Page 39 - Contro_ls

Troubleshooting informationWARNINGTo avoid risk of electrical shock, personal injury, or death, disconnect electrical power source to unit anddischarg

Page 40 - _Pm WARNING

Troubleshooting informationWARNINGTo avoid risk of electrical shock, personal injury, or death, disconnect electrical power source to unit anddischarg

Page 41 - Any Questions?

Troubleshooting informationWARNINGTo avoid risk of electrical shock, personal injury, or death, disconnect electrical power source to unit anddischarg

Page 42 - Warranty

Troubleshooting informationWARNINGTo avoid risk of electrical shock, personal injury, or death, disconnect electrical power source to unit anddischarg