Disassembly Procedures
[ ,Ek WARNING
To avoid risk of electrical shock, personal injury, or death, disconnect electrical power source to unit and
discharge capacitor through a 10,000 ohm resistor before attempting to service, unless test procedures
require power to be connected. Ensure all ground wires are connected before certifying unit as repaired
and/or operational.
]
4. Unbraze condenser discharge connection to
compressor.
5. Unbraze condenser connection shown below.
6. Lift condenser up and away from chassis.
Unbraze Here
Condenser Removal
Compressor Overload Protector Removal
To remove compressor overload protector:
1. Remove chassis (see Chassis Removal).
2. Remove nut securing terminal cover to
compressor, then lift terminal cover up and away
from compressor.
3. Disconnect overload protector leads.
4. Lift overload protector up and away from
compressor.
Overload Terminal Cover
Protecto /
Compressor Overload Protector Removal
Compressor Removal
To remove compressor:
1. Remove chassis (see Chassis Removal).
2. Remove compressor overload protector (see
Compressor Overload Protector Removal).
3. Disconnect leads on compressor.
Note: Before opening any refrigeration system,
capture refrigerant in system for safe disposal.
4. Evacuate sealed system (see Evacuation in
Troubleshooting Information section).
[ CAU'nON J
To reduce risk of personal injury or property damage,
take nescessary precautions against high
J temperatures required for brazing
22 16022061 Rev. 0 @2003 MaytagAppliancesCompany