Before Calling For Service
_Pm WARNING
o reduce the risk of electric shock, personal injury, or death, turn the fan control to the off
osition and remove the unit plug from the wall outlet before doing any inspection or
aintenance work.
The following is a list of problems that are sometimes encountered when using a room air conditioner. Possible cause and
suggested remedies are given for each problem.
If the problem cannot be fixed using the suggested remedies, see WHEN SERVICE IS REQUIRED section.
PROBLEM POSSIBLE CAUSE SUGGESTED REMEDY
UNiT WILL NOT RUN No power to the unit. Set Fan Control to position other than OFF.
Make sure plug is firmly held in outlet.
Check for blown fuses or tripped circuit breakers.
Call for service.
LITTLE OR NO COOLING
NOISY UNIT
Obstructed indoor or outdoor air flow.
Dirty air filters.
Unit undersized for application.
Temperature Control not properly set.
Loose front of mounting assembly.
Weak building construction.
Water hitting the fan blade.
Unit oversized for application.
(Compressor cycles on and off frequently.)
Remove obstruction from indoor grille or outdoor louvers.
Clean the air filter. See Section V for details.
Check with dealer to determine proper capacity unit for your
application.
For cooting turn Temperature Control to higher number.
Call for service.
MOUNTING SUPPORT Storm window frame has been installed into window.
NOT INSTALLED
FROST ON INDOOR COIL Clean the air filter. See Section V for details.
Dirty air filter.
Normal for low outdoor temperatures.
Tighten any loose parts.
Provide additional support for the unit.
Normal in high humidity. Stop noise by removing drain plug or
adding a condensate drain.
Check with dealer to determine proper capacity unit for
application.
Some models require the storm window frame to be removed
before installation.
Turning the Temperature Control to a lower number will reduce
occurrence and duration of frosting condition.
Oversized unit. Check with dealer to determine proper capacity unit for
application.
ODORS tN COOLING Mold, mildew, or algae formation on wet surfaces. To reduce growth use algacide tablet in the unit base pan or
remove drain plug or add a condensate drain. Have your unit
thoroughly cleaned. See Section V.
@2003 MaytagAppliancesCompany 16022061 Rev. 0 A -17